- Q1) What will be the starting current of the motor with the use of Microstart?
- A1) The starting Current depends upon the T-S curves of Load and motor. Typically, the starting current can be controlled up to 1.5 X FLC with the help of Microstart.
- Q2) Typically, which parameters are adjustable at site?
- Q3) Usually which applications are best suited for the use of Microstart?
- A3) Practically, all fixed speed applications can be started using Microstart.
- Q4) Can JAYASHREE modify the Microstart as per the system requirement?
- A4) Yes, as Microstart is the Soft Starter which is 100% manufactured in India with the technical know how from Fairford Electronics ,(U.K.) JAYASHREE can modify the Microstart as per the customers requirement.
- Q5) What else does the user need to arrange / Purchase along with ‘Microstart’ to make the system suitable?
- A5) Nothing at all. JAYASHREE provides the complete solution in a compact Panel,
- Q6) Can JAYASHREE provide the information about the transformer or generator sizing for most economical system designing?
- A6) Yes, JAYASHREE provides complete consultancy for designing of the system using Microstart.
- Q7) What is the range of motors that can be started with the use of Microstart?
- A7) Jayashree Provides a variety of range of products under the Brand Microstart ranging from 0.1KW to 2000KW 415VAC. Special single phase Soft Starters up to 50A are also available.
- Q8) Is it necessary to have expert, trained personnel to install and run the Micro start?
- A8) No, the setting and connections of Micro start are very simple and user friendly and specially designed with the Indian requirement. Any Electrician can also set parameters and install Microstart.
- Q9) Does Microstart require any maintenance and / or servicing?
- A9) No, as there are no moving parts, and all the components of the complete Soft Starter are carefully selected to specially suit the Indian environment , so it is a perfect ‘fit and forget’ type of device and there is absolutely no need of any maintenance and servicing.
- Q10) Is it possible to use single Microstart to start multiple Motors?
- A10) Yes, more than 1 motor of same rating or smaller ratings than the maximum available sized motor in the multi motor scheme can be started using single Microstart panel.
- Q11) How much energy saving can be achieved with the use of Microstart?
- A11) It is case specific and depends upon the motor size and application. JAYASHREE can provide the complete data of energy saving, maximum energy saving achieved. Practically in some cases it is up to 18 –22%. The energy saving calculations can also specify the payback period.
- Q12) IS Micro start is a standard solution and as per standards?
- A12) Yes, Microstart is a standard product strictly designed as per IEC 60947-4-2. / IS 13947 -4 -2.
- Q13) Is it possible to accommodate the Microstart in the exiting panels?
- A13) Yes, the Electronic unit (Open Chains) can be used in the existing panels.
- Q14) Is it possible to use the existing components from the actual installations?
- A14) Yes, retrofitting of the Micro Start along with existing devices (Viz. Start contactor, MCCB, MPR) etc. is possible.